The short answer: there is no single "best" flame-retardant coverall for offshore work. The right one carries the exact norm set your operator or employer specifies, in a fabric weight that suits the climate you work in, with reflective tape and pockets that work with your other kit. For many offshore and petrochemical crews that norm set includes heat and flame (EN ISO 11612), welding (EN ISO 11611), antistatic (EN 1149-5), light chemical splash (EN 13034 Type 6) and arc protection (IEC 61482-2). In the Dapro range, the Roughneck Light Weight Coverall (240 g/m², summer climate), the Globe-Tech Coverall IFR (260 g/m², temperate climate) and the Diamond Coverall (350 g/m², continental climate) each list that full set on their product pages. The final choice always depends on your employer's risk assessment and the site requirements.
This guide walks through the four things to check: fabric weight for your climate, the norms on the label, the reflective tape, and the practical details such as pockets, closures and fit.
1. Start with the norms your site asks for
Offshore operators and contractors often write their own PPE specification, listing the norms (and sometimes the exact performance codes) a coverall must carry. Get that list first. A comfortable coverall that is missing one required norm is the wrong coverall.
What the common norms mean, in plain words
- EN ISO 13688 – general requirements for protective clothing: sizing, ergonomics, labelling and user information. Every coverall below carries it; it says nothing about flame protection on its own.
- EN ISO 11612 – protection against heat and flame. The letters after it show what was tested: A limited flame spread, B convective heat, C radiant heat, D molten aluminium splash, E molten iron splash, F contact heat. The number after each letter is the performance level; level 1 is the entry level for that hazard. If your specification names codes (for example "B1 C1"), check them letter by letter.
- EN ISO 14116 – limited flame spread materials. The index (1 to 3) describes how the fabric behaves when a flame touches it; Index 3 is the highest.
- EN ISO 11611 – clothing for welding and allied processes. Class 1 covers less hazardous welding techniques with lower levels of spatter and radiant heat; Class 2 covers more hazardous ones.
- EN 1149-5 – electrostatic dissipative clothing, so a static charge is not built up and released as a spark. This only works when the garment is fully closed and the wearer is earthed, typically through antistatic safety footwear. Whether it is required depends on your site's hazardous-area classification.
- EN 13034 Type 6 – limited protection against light spray and small splashes of liquid chemicals. It is not a chemical suit; it helps when a small splash happens and you step away.
- IEC 61482-2 – protection against the thermal effects of an electric arc. "Class 1" refers to the box test, in which Class 1 is tested at 4 kA and Class 2 at 7 kA. Some specifications ask for an open-arc value instead (ATPV or ELIM, in cal/cm²). The Dapro product pages below list the box-test class, not an ATPV or ELIM value, so if your specification asks for a cal/cm² figure, ask us before you order.
What each Dapro coverall lists
| Coverall | Fabric weight (product page) | Climate (product page) | EN ISO 11612 | EN ISO 14116 | EN ISO 11611 | EN 1149-5 | EN 13034 Type 6 | IEC 61482-2 | Gas detector loops | Reflective tape | Colours on page |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Roughneck Light Weight | 240 g/m² | Summer | A1 B1 C1 E1 F1 | Index 3 | A1 Class 1 | Yes | Yes | Class 1 | Double, at chest | Prolux® 50 mm FR striping + reflective piping | Navy blue, orange, red, royal blue |
| Globe-Tech IFR | 260 g/m² | Temperate | A1 B1 C1 F1 | Index 3 | A1 Class 1 | Yes | Yes | Class 1 | Double, both sides of chest | Prolux® 50 mm FR striping, hi-vis yellow yokes and piping | Black with hi-vis yellow yokes |
| Diamond | 350 g/m² | Continental | A1 B1 C1 E1 F1 | Index 3 | A1 Class 1 | Yes | Yes | Class 1 | Double, at chest | Prolux® 50 mm FR striping + reflective piping | Navy blue, orange, red, royal blue |
| Roughneck Heavy Weight | Not stated on page | Not stated on page | A1 B1 C1 E1 F1 | Index 3 | A1 Class 1 | Yes | Not listed | Class 1 | Ask us | Ask us | Orange (final stock, limited sizes) |
Norms and codes as listed on each product page on 16 November 2026 (EN ISO 13688 is listed on all four). Always check the garment label and the Declaration of Conformity for the exact codes and standard editions that apply to the garments you receive.
You can see the full range in our flame-retardant coveralls collection or browse all coveralls.
2. Choose the fabric weight for your climate
Once the norms are right, fabric weight is the biggest comfort decision. Dapro labels each coverall for a climate type, which makes this easier:
- Hot climates and summer work – about 240 g/m². The Roughneck Light Weight Coverall is labelled for summer climate. A lighter fabric generally feels cooler over a long shift, and it still lists the full multi-norm set above. It also has side vents behind the side pockets with flame-retardant snap closures.
- Temperate, wet and windy conditions – about 260 g/m². The Globe-Tech Coverall IFR is labelled for temperate climate and has an extra-high collar for wind and rain. "IFR" means inherently flame retardant: the flame resistance comes from the fibres themselves.
- Continental climates and colder seasons – about 350 g/m². The Diamond Coverall is the heaviest fabric of the three and is labelled for continental climate.
Two things to keep in mind:
- Heavier is not automatically safer. The protection level is set by the certification, not by the grams per square metre. A 240 g/m² coverall and a 350 g/m² coverall can list the same norms. Weight changes how warm, stiff and hard-wearing the garment feels.
- Cold offshore weather usually means layers, not just a heavier coverall. Anything you wear over or under an FR coverall affects your protection, so check those layers too. We cover this in our guides to the base layer, the insulating layer and the outer layer.
3. Check the reflective tape
On a platform deck at night, in rain or spray, reflective tape helps others see you. On a flame-retardant coverall the tape itself matters as much as where it sits:
- Use flame-retardant tape. Not every reflective tape is flame retardant, and a tape that burns undermines the coverall it is sewn onto. The Roughneck Light Weight, Globe-Tech and Diamond coveralls use Prolux® 50 mm flame-retardant reflective striping.
- Look at placement. Bands around the arms and legs show movement from every side. The Roughneck Light Weight and Diamond also have reflective piping on the lower sleeves, back pockets and cargo pocket; the Globe-Tech adds high-visibility yellow at the front and back yokes and hi-vis piping on the pockets and lower legs.
- Reflective tape is not the same as hi-vis certification. If your site requires certified high-visibility clothing (EN ISO 20471), check that the garment is certified to it; none of the four coveralls in the table lists EN ISO 20471 on its product page. Our article on Class 2 vs Class 3 high-visibility clothing explains what that standard asks for.
4. Pockets, closures and fit: the details you notice on shift
Offshore work means a gas detector, radio, pens, permits and small tools, often while wearing gloves. Small design details decide whether a coverall works with that kit.
Gas detector loops
A personal gas detector is standard kit on many installations. The Roughneck Light Weight and Diamond have double gas detector loops at the chest; the Globe-Tech has loops on both sides of the chest, so you can clip the detector where your site wants it.
Pockets with flaps
Loose items on a deck can become dropped objects. Look for pockets that close:
- Chest pockets with a safety flap and concealed nylon zipper (Roughneck Light Weight, Globe-Tech, Diamond).
- Leg pockets: a cargo pocket with safety flap on the left leg and a diamond tool pocket with safety flap on the right leg (Roughneck Light Weight, Globe-Tech, Diamond).
- Pen pocket with safety flap on the left sleeve (Roughneck Light Weight, Diamond).
- Back pockets with safety flap and concealed snap closure (all three).
- Shaped kneepad pockets for kneeling on steel decks (all three).
Closures
Exposed metal hardware can heat up and pass that heat to the skin, which is why closures on flame-retardant coveralls are usually concealed:
- Roughneck Light Weight and Diamond: concealed YKK® two-way zipper with metal snap button closure at the front.
- Globe-Tech: a welding flap with concealed plastic flame-retardant snap buttons at the front.
- Cuffs and hems: adjustable cuffs with plastic flame-retardant snap buttons on all three, and adjustable hems on the Roughneck Light Weight and Diamond, so you can close the gap at the wrist and over the boot.
Fit and movement
A coverall only protects when it is fully closed, with sleeves down and legs over the boot tops. The Roughneck Light Weight and Diamond have action armpits for working above shoulder height; all three have back pleats and an adjustable elastic waistband. Check our size guide for coveralls before ordering, especially if you wear thermal layers underneath.
5. Care: keep the protection working
Always follow the care label and the user information supplied with the garment. As a general rule, a flame-retardant coverall soaked in oil, fuel or other flammable substances should be cleaned or taken out of use, because contamination can reduce its protection. Check tape, seams and closures regularly, and replace a garment that is damaged.
Quick checklist before you order
- I have my operator's or employer's PPE specification, including any required performance codes.
- The coverall lists every required norm on its label and Declaration of Conformity.
- If an arc rating in cal/cm² (ATPV or ELIM) is required, I have confirmed it is available.
- The fabric weight suits the climate and season: about 240 g/m² for heat, 260 g/m² for temperate, 350 g/m² for colder continental conditions.
- The reflective tape is flame retardant, and I know whether certified hi-vis is also required.
- The gas detector loops and pockets suit the kit I carry.
- Any layer worn under or over the coverall fits my site's requirements.
- I have checked the size guide with the layers I will wear.
Ordering for a crew? Use our bulk quotation form or email online@dapro-safety.com.
Frequently asked questions
What is the best flame-retardant coverall for offshore work?
The best one is the coverall that carries every norm in your site's PPE specification, in a fabric weight for your climate. Many offshore specifications combine EN ISO 11612, EN ISO 11611, EN 1149-5, EN 13034 Type 6 and IEC 61482-2. In Dapro's range, the Roughneck Light Weight (240 g/m², summer), Globe-Tech IFR (260 g/m², temperate) and Diamond (350 g/m², continental) list all of these on their product pages.
Is a heavier FR coverall more protective?
Not automatically. Protection is defined by the certification and performance codes, not by fabric weight. Weight mainly changes how warm and hard-wearing the coverall feels, so choose it for your climate once the norms are right.
What is the difference between FR and IFR coveralls?
Dapro uses "IFR" for inherently flame-retardant garments, where the flame resistance comes from the fibres themselves, such as the Globe-Tech. Both FR and IFR garments are judged by the same test standards, so compare the norms and codes on the label rather than the abbreviation.
Do Dapro coveralls have an ATPV or ELIM arc rating?
The product pages list IEC 61482-2 Class 1, which is a box-test classification. They do not list an ATPV or ELIM value. If your site specification requires an open-arc value in cal/cm², contact us at online@dapro-safety.com before ordering.
Does an antistatic coverall work on its own?
No. EN 1149-5 clothing needs to be fully closed, and the wearer needs to be earthed, typically through antistatic footwear. Whether antistatic clothing is required depends on your site's hazardous-area classification and risk assessment.
Can I wear a normal jacket over my FR coverall?
Anything worn over a flame-retardant coverall can catch fire and undo its protection, so outer layers should meet the same requirements as the coverall. See our guide to the outer layer for what to look for.
This guide is general information. The final choice of protective clothing depends on your employer's risk assessment and the requirements of the site where you work.